Acceptance Criteria for Shower Room
Feb 07, 2022
Check the size: Check whether there is any error between the measured size and the actual product size.
Check the level: the error should be controlled within 2mm/1000mm.
Check vertical: The horizontal error of the upper and lower vertices on both sides of the shower room should be controlled within 10mm.
Check silica gel: silica gel should be thin, uniform and beautiful.
Checking and closing: The gap of the magnetic door suction strip should be symmetrical, the opening and closing should be flexible, and the opening and closing force should be between 15-40 Newtons.
Check the hinge: The hinge should be smooth and no noise when opening and closing.






